10°C
Porth, Newquay, Cornwall. UK
Updated26/04/2024 20:15 
 




Solar PV - Immersion Heater





29/6/2013 System live at 13:00

Project:- Use excess electric generated to heat the hot water

I heat the hot water by gas, which on average costs 37p per day, based on a sample of 7 days (10th to 17th June 2013), can this be reduced ?

Yes hopefully especially in summer, I wrote an extra script to deal with this, it checks the current output agaist a threshold figure, if its below this nothing happens if above, it switches an ip power switch on which in turn operates a relay putting the immersion heater on, should the output fall below the threshold it switches off the ip relay and contactor and immersion heater, the script checks every 2 minutes output against threshhold setting.

The immersion heater is 3 kw, appears to take less than an hour to heat water,so unless brillant sunshine there will be usage from the grid, say max 1kw that equates to 12.6p, still a possible saving of 25p. Ideal solution would be a 1kw element thereby increasing the time over threshold.

12-10-2023 Takes about 50p to heat water now using gas.

Script and ip power relay installed and electrical work completed. Scripting work not finished, when complete this page will show status of immersion heater/solar pv heating.

immersion

immersion control ip switch

 Immersion Mod Cost

 including p&p
 Meter, switch and cable I already had

IP Power Switch Ebay £112-98
Din Rail Relay Ebay £14-95
Din Rail Enclosure Ebay £4-95
2m Female kettle extn lead Ebay £2-39
  Total £135-27

Solar PV - Immersion Data
Date / Time 26-04-2024 20:22
Threshold - Spring 2800 W
Current Output 0 W
Peak Output 3623 W
Last Update 26-04-2024
Meter # 4445.31
Days solar 2439
Days Gas 1436
Aprrox Savings Gas ## 2439 days @37p = £902.43
# Meter since 29th June 2013, updated most days
## Approx saving on gas,averaged 37p per day


Immersion Data
Date/TimeThresholdOutputAction
26-04-2024 12:52 23002459ON
26-04-2024 12:58 23001908OFF
26-04-2024 13:54 23002375ON
26-04-2024 13:56 23001951OFF
26-04-2024 13:58 23002372ON
26-04-2024 14:04 23002176OFF
26-04-2024 14:36 23002561ON
26-04-2024 14:38 23001477OFF
26-04-2024 14:42 23003646ON
26-04-2024 14:46 23002220OFF
26-04-2024 14:48 23003618ON
26-04-2024 14:54 23001595OFF
26-04-2024 14:56 23003624ON
26-04-2024 14:58 23002216OFF
26-04-2024 15:06 23002855ON
26-04-2024 15:10 23001695OFF
26-04-2024 15:12 23003462ON
26-04-2024 15:14 23001421OFF
26-04-2024 15:52 23002531ON
26-04-2024 15:56 23001960OFF


Immersion Time
Date / Time ONDate / Time OFFTime ONTotal Time On
26-04-2024 12:5226-04-2024 12:5866 mins
26-04-2024 13:5426-04-2024 13:5628 mins
26-04-2024 13:5826-04-2024 14:04614 mins
26-04-2024 14:3626-04-2024 14:38216 mins
26-04-2024 14:4226-04-2024 14:46420 mins
26-04-2024 14:4826-04-2024 14:54626 mins
26-04-2024 14:5626-04-2024 14:58228 mins
26-04-2024 15:0626-04-2024 15:10432 mins
26-04-2024 15:1226-04-2024 15:14234 mins
26-04-2024 15:5226-04-2024 15:56438 mins

Log

17/4/2019 Immersion Heater Replaced
12/4/2019 - Immersion Heater faulty, awaiting plumber
5/4/2017 - 8 SunTech panels replaced with 7 LG panels
2/2/2014 - Added Status of the ip power switch ports
29/6/2013 - Electrical work completed, live at 13:00, then the fog rolled in off the sea.
23/6/2013 Started on addition to script to show minutes on and total time over threshold.

Page under construction - updated 2nd February 2014
Update to display ip switch port status